Deutz 1012 Specifiche Pagina 267

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 282
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 266
Service Training
Section 4.9
Page 41
12.05
FUNCTIONING OF THE VACUUM-CONTROLLED SHUTOFF VALVE
When the engine is off, the shutoff valve is in closed position. No LPG can flow to the vaporisor. When the
engine is started, a vacuum is present in the intake section, which develops through the intake stroke of the
engine. This vacuum is passed through a tube connection from the mixer via connection (11) to the top of
the diaphragm (9) in the shutoff valve. The pressure difference between the top and bottom of the diaphragm
(9) creates an upward displacement of the diaphragm. The diaphragm (9) thereby activates the lever (8)
which acts on the valve shaft (7). The valve shaft (7) is displaced upwards and thereby opens the plate valve
(4) against the initial tension of the leaf spring (5). LPG can now flow through the filter plate (1) to the vaporisor.
6 LPG outlet, filtered
7 Valve shaft
8 Diaphragm lever, to open valve
9 Diaphragm
10 Vacuum space
11 Vacuum inlet from mixer
1 Filter plate
2 Supporting plate, perforated
3 LPG intake
4 Plate valve
5 Leaf spring, to shut valve
Vedere la pagina 266
1 2 ... 262 263 264 265 266 267 268 269 270 271 272 ... 281 282

Commenti su questo manuale

Nessun commento