PROPELLANT GAS MIXER
The correct proportions for the gas-air mixture are important for problem-free running of the engine. For
this purpose, a mixer valve (the mixer) serves for the correct dosing of gas and air.
5 Full load mixture – adjustment screw
6 Gas intake – from vaporisor
7 Transmission tube – vacuum to diaphragm
8 Idling mixture – adjustment screw
1 Mixture outlet to engine
2 Air intake from air filter
3 Vacuum connection – magnet valve, sec-
ondary diaphragm
4 Vacuum connection – shutoff valve